Approx. Rs 75,000 / PieceGet Latest Price
Product Details:
Usage/Application | Industrial |
Brand | Sakova |
Stirrer | Magnetic Stirrer controlled by stir push switch is provide to stir the insulating oil under test |
Weight / Dimension | 60 KV 35 Kgs./375 x 450 x375 mm. approx 100 KV 65 Kgs / 470 x 550 x 450 mm. approx |
Input | 240 Volts,+/- 10%,50 Hz,Single Phase A.C. |
Motor | Constant speed Synchronous motor rising @ 2KV/Sec as per IS6792 |
Current | 10 Ma To 20 Ma (Max) |
Capacity | 1000 VA |
Output | Continuously Variable Between 0 To 60 Kv Or O To 100 Kv |
Accuracy | AccAccuracy +/- 4% Of Full Scale Range uracy +/- 4% Of Ful |
Display | ANALOG or 3.5 Digit Digital LED Display |
Sakova Transformer Oil Bdv Test Set (Motorized Operated) In All H.T. Transformers And Circuit Breakers Etc. Transformer Oil Or Other Insulant Is A Very Important Ingredient. The Liquid Insulant Used Should Have A Very High Dielectric Strength. To Test The Dielectric Strength Of The Insulant, A Very High Voltage Is Passed Through It. The Failure Of The Dielectric Strength Of Insulant Is Shown By A Spark Across Two Electrodes. The Apparatus To Carry Out This Test Is Manufactured By Us In Various High Voltage Ranges , As Per Is:6792 & Iec-156, Known As Sakova Transformer Oil Bdv Test Set.
Control Panel: - Continuously Variable Auto-Transformer (Variac) For Smooth Variation Of Output Voltage, Operated By A Constant Speed Synchronous Motor, 2Kv/Sec As Per Is : 1692/ Iec : 156 Controlled Dec/Inc Toggle Switch. Mains” & “H.T.” “On & Off” Switches, Incorporating Automatic Tripping Mechanism For Protecting The H.T. Transformer Against Overloading.
H.T. Transformer:- H.T. Transformer Is Resin Cast Or Oil Cooled And Of Compact Type, Properly Designed And Treated For Perfect Tropicalization.
Test Cell:- Test Cell Is Made Of Synthetic Polymer And Is Mechanically Tough, Transparent And Non-Absorbent. The Cell Is Complete With Adjustable Gap Electrode Arrangement And Gauge, As Per Is: 6792 And Iec -156
Shock Protection:- The Above Equipment Is Wired And Housed In A Highly Finished Sheet-Metal Cabinet. A Hinged Perspex Cover Is Provided In The Unit For Covering The H.T. Terminals, With Suitable Interlocking Device. The Set Will Not Be Energized Unless The Cover Is Closed. Overload Protection
- Fast Acting Relay Senses The Primary Current Of The H.T. Transformer & Protects The Unit From Overload Protection. Interlocking
- H.T. Cover Interlock And Zero-Start Interlock Are Provided
Technical Data:- Input: 240 Volts, +/- 10%, 50 Hz, Single Phase A.C.
- Output: Continuously Variable Between 0 To 60 Kv Or O To 100 Kv
- Capacity: 1000 Va
- Display: Analog Or 3.5 Digit Digital Led Display
- Accuracy: +/- 4% Of Full Scale Range
- Motor: Constant Speed Synchronous Motor Rising 2Kv/Sec As Per Is6792
- Stirrer: Magnetic Stirrer Controlled By Stir Push Switch Is Provide To Stir The Insulating Oilunder Test. (Optional: Available At Additional Cost)
Short Circuit:- Current: 10 Ma To 20 Ma (Max)
Weight:- Dimension: 60 Kv : 35 Kgs. / 375 x 450 x 375 Mm. Approx
- 100 Kv: 65 Kgs / 470 x 550 x 450 Mm. Approx
Note:- Equipment May Be Supplied With Specification Differing From That Described Above Due To Continuous Development In The Electrical And Mechanical Design.